E- 400 Moisture Cure Primer
Home ] Up ] MSDS Sheets ] EPC News ] Contents ] Contact Info. ] What is Moisture Cure ] Request More Product Information ] Feedback ]

 

PRODUCT INFORMATION:

E-400 PRIME CURE STEEL OVERCOAT SYSTEMS TM

E-400 Moisture Cure Rescue Project
E-400 Moisture Cure Rescue Project
I-75 Rockcastle County

During The E-400 Moisture Cure Rescue Project
During The E-400 Moisture Cure Rescue Project
I-75 Rockcastle County

Final Inspection after E-400 Primer and E-600 finish Coat
Final Inspection after E-400 Primer and E-600 finish Coat
Green River Bridge

Before Cleaning Cumberland County Kentucky
Before Cleaning 
Cumberland County

Before Cleaning Cumberland County Kentucky
Small Amount Of Power Tool Cleaning Necessary For Flash Rust After Water Jetting At 36,000 P.S.I. Before E-400- E-401 and E-600 Finish Coat Is Applied
Small Amount Of Power Tool Cleaning Necessary For Flash Rust After Water Jetting At 36,000 P.S.I. Before E-400- E-401 and E-600 Finish Coat Is

 

Power Wash Chilling Tank
Power Wash Chilling Tank

E-600 Finish Coat Over E-400 Primer
E-600 Finish Coat Over E-400 Primer

 

Before Overcoating With E-Systems
Before Overcoating With E-Systems
JFK Bridge

 

Before E-400 And E-600
Before E-400 And E-600
Red River Forge

 

After E-400 And E-600--Clark County Kentucky
After E-400 And E-600
Clark County

 

A MOISTURE CURE POLYURETHANE NON-LEAFING ALUMINUM PRIMER

STEEL OVERCOAT SYSTEMS E-400 IS AN ECONOMICAL, ONE COMPONENT, ENVIRONMENT FRIENDLY MOISTURE CURE PRIMER OF HIGH SOLID NON-LEAFING ALUMINUM.
COLOR: SILVER 
FINISH: FLAT
CHEMICAL FAMILY: POLY ISOCYANATE - PREPOLYMER

USES:

STEEL OVERCOAT SYSTEMS E-400 IS EXCELLENT FOR OVERCOATING
STRUCTURAL STEEL AND OTHER METAL SURFACES WHEN LITTLE PREPARATION IS DESIRED TO ACCOMMODATE FIRST STAGE ENCAPSULATION OF RUST,CORROSION AND OLD LEAD PAINT. 
STEEL OVERCOAT SYSTEMS E-400 ELIMINATES THE NEED FOR SAND BLASTING WHEN 4000+ P.S.I. WATER BLASTING AND A REASONABLE AMOUNT OF POWER AND HAND TOOL CLEANING IS DONE. 
STEEL OVERCOAT SYSTEMS E-400'S ABILITY TO ENCAPSULATE OLD PAINT AND RUST IS ENHANCED WHEN A SECOND COAT IS USED BEFORE TOP COATING. 
STEEL OVERCOAT SYSTEMS E-400 MUST BE TOP COATED IN EVERY INSTANCE, DUE TO PRIMERS LACK OF LIGHT STABILIZERS. 
STEEL OVERCOAT SYSTEMS E-400 AFFORDS HIGH RESISTANCE TO CORROSION, MOISTURE, CHEMICALS, ABRASION AND UNDERCUTTING.

 

SURFACE PREPARATION:

SURFACES MUST BE FREE FROM ALL MOISTURE, DIRT, OIL, GREASE AND OTHER CONTAMINANTS. FOR BEST RESULTS, POWER WASH AND TOOL CLEAN, THEN BRUSH FIRST COAT OVER SUBSTRATE BEFORE APPLYING SECOND COAT WITH BRUSH, ROLLER OR SPRAY.

PRODUCT TECHNICAL DATA:

WEIGHT SOLIDS: 69.0 +. 2.0 %.
WEIGHT PER GAL:  9.6 LBS. PER GAL.+-O.2 LBS. PER GAL.
VOLUME SOLIDS:  59.19 % +- 1.5 %
VOC LBS. PER GAL: 2.71 LBS.  
GRAMS PERIL 322.1


 

RECOMMENDED D.F.T.: 2 - 3 MILS DRY.
CURING TIME:  
TO TOUCH 3 HRS.
TO HANDLE 3-4 HRS.
TO RECOAT 4 HRS. 0 77 F. @ 50% R. HUMIDITY.
TO RECOAT IN BELOW NORMAL TEMP- 24 HRS.
STORAGE LIFE:  ONE YEAR @ 77 F. ( 25 C )


APPLICATION PROCEDURES: 

PREPARE PRODUCT BY THOROUGHLY STIRRING, MAKING SURE NO PIGMENTS STAY ON BOTTOM. 
KEEP PRODUCT CONTAINER CLOSED WHEN NOT USING, SINCE PRODUCT REACTS TO MOISTURE. 
DO NOT THIN, SINCE VISCOSITY WILL REMAIN CONSTANT WHEN CONTAINER STAYS CLOSED.
APPLY WITH BRUSH, SPRAY OR ROLLER.

AIRLESS SPRAY: 

USE TIP SIZE 0.017 OR 0.013. HOSE SIZE: 114 TO 318
INCH. FILTER: USE 60 MESH.

RECOAT TIME:

FOR COLD WEATHER APPLICATION, A LONGER DRYING TIME IS RECOMMENDED, A MINIMUM OF NO LESS THAN 24 HRS. 
FOR WARM TO HOT WEATHER RECOAT TIME MAY BE SHORTENED TO AS LITTLE AS 4 HRS. 
MUST BE RECOATED WITHIN 5 DAYS.
SURFACE TEMPERATURE MUST BE AT LEAST FIVE [5} DEGREES ABOVE DEW POINT BEFORE APPLICATION.
FOR ADDITIONAL INFORMATION, CONTACT US.
COVERAGE RATES:
SPRAY, BRUSH OR ROLLER:

WET MILLS 3.5 = 2.5 MILS DFT=APPROX: 425 SQ. FT. PER GALLON

WET MILLS 4.5=3.0 MILS DFT= APPROX: 360 SQ. FT. PER GALLON

FOR HIGH BUILD-SPRAY ONLY:

WET MILLS 7.5 = 5.0 MILS DFT = APPROX: 225 SQ. FT. PER GALLON

WET MILLS 6.0 4.0 MILS DFT = APPROX: 275 SQ. FT. PER GALLON

WET MILLS 4.5 = 3.0 MILS DFT = APPROX: 375 SQ. FT. PER GALLON

SAG RESISTANCE:

NO SAG ON LENATA DRAWDOWN SCALE THROUGH 6 WET MILS.

1/32" DRAG @ 8 MILS WET.


CLEANUP: USE (XYOL) XYLENE TO FLUSH AND CLEAN IMMEDIATELY AFTER EQUIPMENT USE. DO NOT ALLOW MOISTURE OR ALCOHOL NEARPRODUCT OR EQUIPMENT.

SAFETY PROCEDURES: SEE  MSDS Sheet 

E- 300 Moisture Cure Coal Tar Top Coat ] [ E- 400 Moisture Cure Primer ] E- 401 Moisture Cure Primer ] E- 500 Moisture Cure M.I.O ] E- 500 MIO Article ] E- 600 Finish Coat ] E- 600 Test Results ] E- 700 S.O.S. Polyester Finish Coat ] E- 2000  Moisture Cure Primer Sealer ] EZ- 2800 Moisture Cure  Zinc Rich Coating ] EZ- 2800 Test Results ] E- 8000 Diamond Crystal Clearcoat ] E- 8000 News Article ] Oxi- Bloc Industrial Maintenance Coating ] THERM-A-SHIELD  Acrylic Roof Coating ] NU  ROOF Elastomeric Roof Coating Product ] Contractor Product References ]