Recommend this page Printer Friendly

Product Information:

 

Poly-Flo HiE is a sprayable, VOC free , Two component, pure polyurea elastomeric membrane. Its low viscosity at operational temperatures makes it a product ideal for both in-plant and field applications. Unique properties of this coating are its rapid cure time and its insensitivity to moisture.

 

Advantages

  • Almost instant gel time
  • Can be Handled/Walked on in 1 minute
  • Can be built up to any thickness in one application
  • Seamless and flexible
  • Application at -20 F to + 300 F
  • Resists thermal shock
  • Resistance to many chemicals
  • Waterproofing
  • No VOC's
  • USDA Approved

Uses

  • Earthen Containment
  • Pipe Coating
  • Containment Areas Floor and Wall Systems
  • Waste Water
  • Cold Storage Areas
  • Tank Linings
  • Cooling Tower Basins
  • Pulp and Paper Mills
  • Industrial Plants
  • Mechanical Rooms
  • Aquariums
  • Fertilizer Plants
  • Bridges
  • Manhole Vaults
  • Wet Wells
  • Dry Wells
  • Street Lights
  • Lift Station Waterproofing
  • Zoo Enclosures Dairy Barn
  • Walls and Floors
 

Application

Correct equipment is critical to the installation, use only 1:1 ratio, heated plural component equipment, similar to the H-2000, H-3500, and the new H-20/35, series with a GX7, GX7-400.

Consult a EPC representative for information.. Poly-Flo HiE must be sprayed at a minimum of 2000 psi and 160 F at the gun.

 

Installation

Consult EPC, for an approved applicator and for job specific Specifications.. Apply to clean dry sound surfaces free of loose particles or other foreign matter. Consult EPC for surface preparation and repair procedures.

Limitations

  • Intended for Industrial use
  • Poly-Flo HiE is an aromatic, although physical properties will change, over a period of time color change will occur.
  • Consult EPC for corrosive applications.
  • Do not install in Moisture/Vapor conditions>Lbs. MVT >5% moisture content.
  • Primer may be required.
  • Avoid moisture contamination in containers.
  • Refer to MSDS, instruction sheet and product labels.

 

PHYSICAL PROPERTIES
Test Method
Value
Elongation
D-638
800%
Tensile Strength
D-638
3000 psi
Shore Hardness

D-2240

D-50
Tear Strength
D-624
475 pli
Moisture Vapor Transmission

E-96

0.02 perm

Abrasion Resistance (wt. loss mg)

 

1000g., 1000 rev. H-18
D-4060
170mg
1000g., 1000 rev. CS17
D-4060
<5 mg
     

100% Modulus (psi)

D-638
1600 psi
300% Modulus (psi)
D-638
1900 psi
 
Coefficient of Thermal Expansion

C-352

4x10/-3 (1in/1in/C)
Flash Point, components
>200°F
Flame Spread
E-108
Class A (Comparable to UL 790)
Gel Time / Tack Free
6/20 Seconds
 
Flexibility Testing
Gardner Impact in.-lbs
(on 1/32 Steel Panels) Direct and Indirect

D-2794

>160 in.-lbs

 

Mandrel Bend

Conical Bend (on 1/32" steel panels)

D-522
Pass
¼" Mandrel 25°C (free film 30-50 mils)
D-1737
Pass
¼" Mandrel -20°C (free film 35-50 mils)
D-1737
Pass
 
Puncture Resistance, lbs.
D-4833
325 lbs .

 

 